415V Breaker

  • EPS 4 Pole 100A 300mA Main Incoming Fire Protection ELCB RCCB for 3-Phase System Safety IEC 61008-1 Compliant Sumon Electrical Subang Jaya USJ 14 Selangor
    Electrical & Power Systems

    EPS 4 Pole 100A 300mA ELCB | Heavy-Duty 3-Phase Main Fire Protection RCCB

    RM278.00 Add to cart
    • Sensitivity: 300mA (0.3A) – Dedicated to Global Fire & Installation Safety.

    • Current Rating: 100 Amperes Continuous Load Capacity.

    • Configuration: 4 Pole (Complete 3-Phase & Neutral Isolation).

    • Voltage Compatibility: 415V~ 50/60Hz Three-Phase Systems.

    • Standard Compliance: Certified to IEC 61008-1 & SIRIM Approved.

    • Testing: Front-mounted Yellow Monthly Operational Test Mechanism.

  • EPS 4 Pole 100A 30mA High Sensitivity Main Incoming ELCB RCCB for 3-Phase System Safety IEC 61008-1 Compliant Sumon Electrical Subang Jaya USJ 14 Selangor
    Electrical & Power Systems

    EPS 4 Pole 100A 30mA ELCB | High-Sensitivity 3-Phase Main Safety RCCB

    RM328.00 Add to cart
    • Sensitivity: 30mA (0.03A) – High-Sensitivity Threshold for Maximum Human Protection.

    • Current Rating: 100 Amperes Heavy-Duty Capacity.

    • Configuration: 4 Pole (4P Full Line & Neutral Interruption).

    • Voltage Compatibility: 415V~ 50/60Hz Three-Phase Systems.

    • Standard Compliance: Certified to IEC 61008-1 & SIRIM Approved.

    • Testing: Integrated Front-facing Yellow Safety Testing Button.

  • EPS 4 Pole 40A 100mA Main Incoming ELCB RCCB for 3-Phase Electrical Safety IEC 61008-1 Compliant Sumon Electrical Subang Jaya USJ 14 Selangor
    Electrical & Power Systems

    EPS 4 Pole 40A 100mA ELCB | 3-Phase Main Circuit Safety RCCB

    RM98.00 Add to cart
    • Sensitivity: 100mA (0.1A) – Optimal for Balanced 3-Phase Sub-Boards & Main Lines.

    • Current Rating: 40 Amperes Capacity.

    • Configuration: 4 Pole (Complete 3-Phase Line & Neutral Isolation).

    • Voltage Compatibility: 415V~ 50/60Hz Three-Phase.

    • Standard Compliance: Fully Conforms to IEC 61008-1 & SIRIM Approved.

    • Maintenance: Integrated Front Yellow Monthly Safety Test Button.

  • EPS 4 Pole 40A 300mA Main Incoming Fire Protection ELCB RCCB for 3-Phase System Safety IEC 61008-1 Compliant Sumon Electrical Subang Jaya USJ 14 Selangor
    Electrical & Power Systems

    EPS 4 Pole 40A 300mA ELCB | Heavy-Duty 3-Phase Main Fire Protection RCCB

    RM96.00 Add to cart
    • Sensitivity: 300mA (0.3A) – Dedicated to Macro-Level Property Fire Prevention.

    • Current Rating: 40 Amperes Capacity.

    • Configuration: 4 Pole (Complete Three-Phase Line & Neutral Isolation).

    • Voltage Compatibility: 415V~ 50/60Hz Three-Phase Systems.

    • Standard Compliance: Fully Conforms to IEC 61008-1 & SIRIM Approved.

    • Maintenance: Integrated Front Yellow Monthly Safety Test Button.

  • EPS 4 Pole 40A 30mA High Sensitivity Main Incoming ELCB RCCB for 3-Phase System Safety IEC 61008-1 Compliant Sumon Electrical Subang Jaya USJ 14 Selangor
    Electrical & Power Systems

    EPS 4 Pole 40A 30mA ELCB | High-Sensitivity 3-Phase Safety RCCB

    RM118.00 Add to cart
    • Sensitivity: 30mA (0.03A) – High-Sensitivity Threshold for Maximum Human Protection.

    • Current Rating: 40 Amperes Load Capacity.

    • Configuration: 4 Pole (4P Full Line & Neutral Interruption).

    • Voltage Compatibility: 415V~ 50/60Hz Three-Phase Systems.

    • Standard Compliance: Certified to IEC 61008-1 & SIRIM Approved.

    • Testing: Integrated Front-facing Yellow Safety Testing Button.

  • EPS 4 Pole 63A 300mA Main Incoming Fire Protection ELCB RCCB for 3-Phase System Safety IEC 61008-1 Compliant Sumon Electrical Subang Jaya USJ 14 Selangor
    Electrical & Power Systems

    EPS 4 Pole 63A 300mA ELCB | 3-Phase Main Fire Protection RCCB

    RM96.00 Add to cart
    • Sensitivity: 300mA (0.3A) – Dedicated to System-Wide Property Fire Prevention.

    • Current Rating: 63 Amperes Continuous Load Capacity.

    • Configuration: 4 Pole (Complete Three-Phase & Neutral Isolation).

    • Voltage Compatibility: 415V~ 50/60Hz Three-Phase Systems.

    • Standard Compliance: Fully Conforms to IEC 61008-1 & SIRIM Approved.

    • Maintenance: Integrated Front Yellow Monthly Safety Test Button.

  • EPS 4 Pole 63A 30mA High Sensitivity Main Incoming ELCB RCCB for 3-Phase System Safety IEC 61008-1 Compliant Sumon Electrical Subang Jaya USJ 14 Selangor
    Electrical & Power Systems

    EPS 4 Pole 63A 30mA ELCB | High-Sensitivity 3-Phase Safety RCCB

    RM122.00 Add to cart
    • Sensitivity: 30mA (0.03A) – High-Sensitivity Threshold for Maximum Human Protection.

    • Current Rating: 63 Amperes Load Capacity.

    • Configuration: 4 Pole (4P Full Line & Neutral Interruption).

    • Voltage Compatibility: 415V~ 50/60Hz Three-Phase Systems.

    • Standard Compliance: Certified to IEC 61008-1 & SIRIM Approved.

    • Testing: Integrated Front-facing Yellow Safety Testing Button.